Had the same problem Gary and thanks for the diagnosis! mine was a little red button on the top of the boiler! It clicked in as pressure was applied! Cheers mate alot of stress saved!!
Adam August 2012 |
Wow... thanks. Worcester 24i same prblem. Just stopped working dont know why. The air preassure switch is the little threaded one at the front leftt of the boiler on the top. Mine was like a dark brown in colour and it was reset with very little preassure from me.
Great site!
Greg, SW20 September 2009 |
After ours made an awful racket when stopping the hot tap with heating on . I had the same fault.
The answer of the common air pressure switch led me to a unit that sits sticking out the top of the boiler.
There was a small pin sticking up so i pressed it down with mild pressure and it moved.
After the pin had moved the boiler worked fine.
So two things THANK YOU for the "Answer"
And
This can possibly be fixed without having to take the covers off.
Gary from Plymouth December 2008 |
what is the flu?X
adrienne February 2008 |
air pressure switch, if the fan is running, very common fault on these
shaun
chippercat5@hotmail.com April 2007 |